2 changes: 1 addition & 1 deletion Changelog.md
Original file line number Diff line number Diff line change
Expand Up @@ -7,7 +7,7 @@ __Features__

__Bugfixes__
- **Breaking change**: Prevent possible error if HPWH in confined space with very small containment volume; minimum allowed volume now 32 ft3.
- **Breaking change**: HPWH `EnergyFactor`/`UniformEnergyFactor` must now be >= 2 (previously > 1).
- **Breaking change**: HPWH `EnergyFactor`/`UniformEnergyFactor` must now be >= 1.45 (previously > 1).
- Fixes ERV supply outlet enthalpy calculation used to calculate latent effectiveness.
- Removes duplicated ceiling/floor internal mass surfaces between conditioned stories.

Expand Down
8 changes: 4 additions & 4 deletions HPXMLtoOpenStudio/measure.xml
Original file line number Diff line number Diff line change
Expand Up @@ -3,8 +3,8 @@
<schema_version>3.1</schema_version>
<name>hpxml_to_openstudio</name>
<uid>b1543b30-9465-45ff-ba04-1d1f85e763bc</uid>
<version_id>33bfdc9e-84c0-409d-bc66-ca2781e23cf0</version_id>
<version_modified>2026-07-15T22:44:01Z</version_modified>
<version_id>b5a80774-bddd-4161-b29c-68607900018d</version_id>
<version_modified>2026-07-16T19:57:35Z</version_modified>
<xml_checksum>D8922A73</xml_checksum>
<class_name>HPXMLToOpenStudio</class_name>
<display_name>HPXML to OpenStudio Translator</display_name>
Expand Down Expand Up @@ -421,7 +421,7 @@
<filename>hpxml_schematron/EPvalidator.sch</filename>
<filetype>sch</filetype>
<usage_type>resource</usage_type>
<checksum>423C115C</checksum>
<checksum>277C72EB</checksum>
</file>
<file>
<filename>hpxml_schematron/iso-schematron.xsd</filename>
Expand Down Expand Up @@ -829,7 +829,7 @@
<filename>test_validation.rb</filename>
<filetype>rb</filetype>
<usage_type>test</usage_type>
<checksum>F7D696DC</checksum>
<checksum>9ABBBD64</checksum>
</file>
<file>
<filename>test_vehicle.rb</filename>
Expand Down
5 changes: 3 additions & 2 deletions HPXMLtoOpenStudio/resources/hpxml_schematron/EPvalidator.sch
Original file line number Diff line number Diff line change
Expand Up @@ -2139,8 +2139,9 @@
<sch:assert role='ERROR' test='count(h:FractionDHWLoadServed) = 1'>Expected FractionDHWLoadServed</sch:assert>
<sch:assert role='ERROR' test='number(h:HeatingCapacity) &gt; 0 or not(h:HeatingCapacity)'>Expected HeatingCapacity to be greater than 0.</sch:assert>
<sch:assert role='ERROR' test='count(h:UniformEnergyFactor) + count(h:EnergyFactor) = 1'>Expected UniformEnergyFactor or EnergyFactor but not both</sch:assert>
<sch:assert role='ERROR' test='number(h:UniformEnergyFactor) &gt;= 2 or not(h:UniformEnergyFactor)'>Expected UniformEnergyFactor to be greater than or equal to 2</sch:assert>
<sch:assert role='ERROR' test='number(h:EnergyFactor) &gt;= 2 or not(h:EnergyFactor)'>Expected EnergyFactor to be greater than or equal to 2</sch:assert>
<!-- Note: We need to allow modeling HPWHs w/ EF/UEF around 1.5 for ENERGY STAR and DOE Efficient New Home ERI targets -->
<sch:assert role='ERROR' test='number(h:UniformEnergyFactor) &gt;= 1.45 or not(h:UniformEnergyFactor)'>Expected UniformEnergyFactor to be greater than or equal to 1.45</sch:assert>
<sch:assert role='ERROR' test='number(h:EnergyFactor) &gt;= 1.45 or not(h:EnergyFactor)'>Expected EnergyFactor to be greater than or equal to 1.45</sch:assert>
<sch:assert role='ERROR' test='h:HPWHOperatingMode[text()="hybrid/auto" or text()="heat pump only"] or not(h:HPWHOperatingMode)'>Expected HPWHOperatingMode to be 'hybrid/auto' or 'heat pump only'</sch:assert>
<sch:assert role='ERROR' test='count(h:extension/h:HPWHInConfinedSpaceWithoutMitigation) &lt;= 1'>Expected at most one extension/HPWHInConfinedSpaceWithoutMitigation</sch:assert>
<sch:assert role='ERROR' test='h:extension/h:HPWHInConfinedSpaceWithoutMitigation[text()="true" or text()="false"] or not(h:extension/h:HPWHInConfinedSpaceWithoutMitigation)'>Expected extension/HPWHInConfinedSpaceWithoutMitigation to be 'true' or 'false'</sch:assert>
Expand Down
4 changes: 2 additions & 2 deletions HPXMLtoOpenStudio/tests/test_validation.rb
Original file line number Diff line number Diff line change
Expand Up @@ -75,7 +75,7 @@ def test_schema_schematron_error_messages
'dehumidifier-fraction-served' => ['Expected sum(FractionDehumidificationLoadServed) to be less than or equal to 1 [context: /HPXML/Building/BuildingDetails, id: "MyBuilding"]'],
'dhw-frac-load-served' => ['Expected sum(FractionDHWLoadServed) to be 1 [context: /HPXML/Building/BuildingDetails, id: "MyBuilding"]'],
'dhw-invalid-ef-tank' => ['Expected EnergyFactor to be less than 1 [context: /HPXML/Building/BuildingDetails/Systems/WaterHeating/WaterHeatingSystem[WaterHeaterType="storage water heater"], id: "WaterHeatingSystem1"]'],
'dhw-invalid-uef-tank-heat-pump' => ['Expected UniformEnergyFactor to be greater than or equal to 2 [context: /HPXML/Building/BuildingDetails/Systems/WaterHeating/WaterHeatingSystem[WaterHeaterType="heat pump water heater"], id: "WaterHeatingSystem1"]'],
'dhw-invalid-uef-tank-heat-pump' => ['Expected UniformEnergyFactor to be greater than or equal to 1.45 [context: /HPXML/Building/BuildingDetails/Systems/WaterHeating/WaterHeatingSystem[WaterHeaterType="heat pump water heater"], id: "WaterHeatingSystem1"]'],
'dishwasher-location' => ['A location is specified as "garage" but no surfaces were found adjacent to this space type.'],
'duct-leakage-cfm25' => ["The value '-2.0' is less than the minimum value allowed",
"The value '-3.0' is less than the minimum value allowed"],
Expand Down Expand Up @@ -326,7 +326,7 @@ def test_schema_schematron_error_messages
hpxml_bldg.water_heating_systems[0].recovery_efficiency = nil
when 'dhw-invalid-uef-tank-heat-pump'
hpxml, hpxml_bldg = _create_hpxml('base-dhw-tank-heat-pump.xml')
hpxml_bldg.water_heating_systems[0].uniform_energy_factor = 1.5
hpxml_bldg.water_heating_systems[0].uniform_energy_factor = 1.4
Comment thread
shorowit marked this conversation as resolved.
when 'dishwasher-location'
hpxml, hpxml_bldg = _create_hpxml('base.xml')
hpxml_bldg.dishwashers[0].location = HPXML::LocationGarage
Expand Down
2 changes: 1 addition & 1 deletion docs/source/workflow_inputs.rst
Original file line number Diff line number Diff line change
Expand Up @@ -4241,7 +4241,7 @@ Each heat pump water heater is entered as a ``/HPXML/Building/BuildingDetails/Sy
``FractionDHWLoadServed`` double frac >= 0, <= 1 [#]_ Yes Fraction of hot water load served [#]_
``HeatingCapacity`` double Btu/hr > 0 No See [#]_ Heating input capacity
``BackupHeatingCapacity`` double Btu/hr >= 0 No 15355 (4.5 kW) Heating capacity of the electric resistance backup
``UniformEnergyFactor`` or ``EnergyFactor`` double frac >= 2, <= 5 Yes EnergyGuide label rated efficiency
``UniformEnergyFactor`` or ``EnergyFactor`` double frac >= 1.45, <= 5 Yes EnergyGuide label rated efficiency
``HPWHDucting/ExhaustAirTermination`` string See [#]_ No <none> The location where HPWH exhaust air is ducted to
``HPWHOperatingMode`` string See [#]_ No hybrid/auto Operating mode [#]_
``UsageBin`` or ``FirstHourRating`` string or double str or gal/hr See [#]_ or > 0 No See [#]_ EnergyGuide label usage bin/first hour rating
Expand Down