Automated J–V Characterisation & SPO Degradation Testing Platform
University of Stuttgart · Institut für Photovoltaik (ipv)
- Overview
- Key Features
- System Architecture
- Hardware Requirements
- Installation
- Running the Application
- Application Workflow
- Solar Cell Metrics
- Device Architecture: n‑i‑p vs p‑i‑n
- SPO — Set‑Point Operation
- Testing
- Building Standalone Applications
- Project Structure
- Configuration
- Data Format
- Development Guide
- License
SolarJV Analyzer is a Python-based, PyQt5 graphical application for automated, multi-channel J–V (current–voltage) sweep characterisation and SPO (Set‑Point Operation) long-term stability testing of solar cells. It provides a complete experimental pipeline: from instrument control to real-time visualisation, on-the-fly solar cell metric extraction, and structured data export.
The software interfaces directly with a Keithley 2400 SourceMeter and a 6‑channel multiplexer to measure up to six solar cells sequentially in a single experimental run. It supports dual-direction sweeps (forward + reverse) for hysteresis analysis and device architecture selection (n‑i‑p / p‑i‑n) with quadrant-agnostic metric computation.
Designed and maintained at the Institute for Photovoltaics (ipv), University of Stuttgart, this tool replaces manual lab-book workflows with a reproducible, auditable, and user-friendly measurement platform.
| Feature | Description |
|---|---|
| Multi-Channel J–V Sweeps | Hardware-controlled staircase sweeps on up to 6 channels via the Keithley 2400's built-in trigger model and buffer |
| Dual-Direction Sweeps | Per-channel Forward + Reverse sweeps with automatic hysteresis-aware metric extraction |
| SPO Stability Testing | Constant-voltage hold with configurable duration, sampling interval, and pre-conditioning time |
| Real-Time Plotting | Live I–V and Power–vs–Time curves via pyqtgraph with channel-coloured traces |
| Instrument Status | Red/green connectivity lights for Keithley and MUX |
| Feature | Description |
|---|---|
| 14 Solar Cell Metrics | EFF, FF, Voc, Jsc, Vmpp, Jmpp, Pmpp, Isc, Rsh, Rs, Rho_shunt, Rsq, Area, Incident Power |
| Quadrant-Agnostic | Automatically handles both n‑i‑p (Q4: V>0, I<0) and p‑i‑n (Q2: V<0, I>0) architectures. Metrics report positive magnitudes except Vmpp, which keeps its sign (negative for p‑i‑n) so the SPO hold polarity is correct |
| Anchored Local-Parabola MPP | Global measured optimum anchors an adaptive-window local quadratic fit with iterative recentering — tracks sharp MPP knees without global-polynomial underfit, averages noise on flat maxima |
| Curvature-Aware Voc/Isc | Local regression at the zero crossing with residual-gated quadratic refinement; no crossing → NaN, never an extrapolated (fabricated) value |
| Rs / Rsh Extraction | Voltage-span-selected local slope regression (±max(2·step, 25 mV)) at V=Voc (Rs) and V=0 (Rsh) |
| SPO Metrics | Mean power, standard deviation, drift percentage, energy yield (trapezoidal integration), peak/trough power |
| Feature | Description |
|---|---|
| Structured CSV Export | Experiment parameters, analysis summary, and measurement data in a single self-documenting file with [[ EXPERIMENTAL PARAMETERS ]], [[ ANALYSIS SUMMARY ]], and [[ MEASUREMENT DATA ]] block tags |
| File Loading & Restoration | Previously saved measurement files are fully restored — plot curves, browser tree, analysis matrix, and channel data |
| Crash-Safe SPO Logging | Every SPO sample is flushed to disk immediately with fsync — a crash never loses previously recorded data |
| User Authentication | SQLite-backed login system with Argon2id password hashing, registration, password reset, and timestamped session logs |
| Directory Management | Automatic Base/Username/Date/{Calibration|JV|SPO}/ folder structure, where Username is the application login — see Data storage and attribution |
| Filename Validation | Execution buttons are gated on a non-empty filename prefix — prevents orphaned data files |
| Feature | Description |
|---|---|
| Dark-Themed Login Screen | Premium split-screen design with full-bleed lab illustration and frosted-glass form card |
| Full-Screen Operation | Calibration and Main windows open maximised |
| Centred Pill Tab Bar | Bottom dashboard with mint-green pill-style tab selectors for Experiment Queue and Channel Analysis |
| Persistent Action Bar | Show all / Hide all / Clear all / Open controls visible in both views |
| Channel Colour Badges | Vibrant channel indicators in the action bar matching plot curve colours |
| Architecture Badge | n‑i‑p / p‑i‑n indicator in the action bar |
| Dynamic Selection Highlight | Row selection in the analysis matrix highlights in the selected channel's exact plot colour |
Every measurement is filed under the name the operator signed into the application with:
S:\Data\JV\<app login>\<yyyy-mm-dd>\<Calibration|JV|SPO>\
The same name is used for the local working folders, so a given person's data appears under one name everywhere.
The folder name used to come from the Windows process token, which nobody can spoof. Every lab machine now runs under a single shared Windows account, so that name is identical for everyone and would file all operators' data into one folder with no attribution at all. The application login is what distinguishes people, so it is what names the folder.
Two consequences follow from that choice:
- Nothing publishes before login. The store holds finished files and session logs in staging until somebody signs in — an unattributed folder is worse than a delayed one. This is normal at startup, not an error.
- The identity is not cached. One process can serve several operators via the re-login loop, so the name is set at login and cleared at logout. Logging out triggers a final publish first, so a departing operator's files never land in the next person's folder.
Attribution is now only as strong as the password protecting an account. Account creation is self-service from the login screen and only checks that the username is non-empty and unique, so the store records who signed in, not a fact verified by the operating system. That is appropriate for a shared lab instrument; it is not an audit trail.
The publisher only takes files that have been quiet for
STORE_QUIET_SECONDS. A file still being written at the moment of logout stays
in staging and is published on a later tick — under whoever is signed in then.
In practice a run is finished long before anyone logs out, but if you abort a
measurement and immediately log out, check that the file landed in the right
folder.
┌──────────────┐ ┌─────────────────┐ ┌──────────────────────┐
│ Login │────▶│ Calibration │────▶│ Main Analyzer │
│ Dialog │ │ Window │ │ Window │
│ (auth.db) │ │ (reference │ │ (J-V Sweeps + SPO) │
│ │ │ cell check) │ │ │
└──────────────┘ └─────────────────┘ └──────────────────────┘
│
┌────────────────────────────┼────────────────────────────┐
│ │ │
┌──────▼──────┐ ┌───────▼───────┐ ┌────────▼────────┐
│ JV Sweep │ │ SPO Testing │ │ File Loading │
│ (PyMeasure │ │ (QThread │ │ & Analysis │
│ Manager) │ │ Worker) │ │ Restoration │
└──────┬──────┘ └───────┬───────┘ └────────┬────────┘
│ │ │
┌──────▼──────┐ ┌───────▼───────┐ ┌────────▼────────┐
│ JVProcedure │ │ SpoProcedure │ │ AppController │
│ (Keithley │ │ (inherits │ │ (parse, merge, │
│ staircase │ │ JVProcedure) │ │ format, load) │
│ sweep) │ │ │ │ │
└──────┬──────┘ └───────┬───────┘ └────────┬────────┘
│ │ │
┌──────▼────────────────────────────▼───────────────────────────▼────────┐
│ compute_jv_metrics / compute_spo_metrics │
│ (Pure computation — no hardware dependency) │
└─────────────────────────────────────────────────────────────────────────┘
| Layer | Technology |
|---|---|
| UI Framework | PyQt5 + pyqtgraph |
| Measurement Engine | PyMeasure (Procedure / Manager / Worker) |
| Instrument Control | PyVISA (Keithley 2400), PySerial (MUX hex protocol) |
| Numerical Analysis | NumPy, SciPy (linregress, lstsq, trapezoid) |
| Data Management | Pandas (CSV parsing, DataFrame multi-index) |
| Authentication | SQLite + Argon2id password hashing |
| Packaging | Hatchling (build), Briefcase (native macOS .dmg / Windows .msi) |
| Testing | pytest (110 tests, 13 test files) |
Main GUI Thread (PyQt5 event loop)
│
├── JV Sweeps → PyMeasure Manager → Worker threads (blocking I/O safe)
│
├── SPO Runs → SpoWorker (QThread subclass, custom lifecycle)
│
└── All data emitted back via Qt signals (pyqtSignal) — thread-safe
Critical Rule: PyVISA and PySerial calls MUST never execute on the main GUI thread. All hardware communication runs in background workers.
| Instrument | Model | Interface | Protocol |
|---|---|---|---|
| SourceMeter | Keithley 2400 | USB / GPIB | VISA (SCPI commands) |
| Multiplexer | 6-channel custom MUX | Serial (RS-232) | Hex protocol (AA010{pixel}000000BB) |
Before each measurement session, the calibration gate verifies:
- Chiller, Sun Simulator, and Keithley powered ON
- Wavelabs "AM1.5G" recipe loaded
- Silicon reference cell (RERA) placed correctly
- Lamp height verified at 46.8 cm
A fast J‑V sweep on the reference cell must pass Isc tolerance (±5% of target) before the main application unlocks.
Setting up a lab PC from scratch (no Python, no drivers)? Follow
docs/install-windows.mdinstead — it covers the Python install, the VISA backend, USB-serial drivers, COM-port configuration and first login, step by step.
- Python ≥ 3.8 (development), exactly 3.9 (Briefcase packaging).
Python ≥ 3.11 if you use the pinned
requirements-windows.txt. - NI-VISA or PyVISA-py backend for Keithley communication
- Serial port access for MUX communication
git clone https://github.com/uni-stuttgart-ipv/jv_setup_keithley_controller.git
cd jv_setup_keithley_controller
python -m venv .venv
source .venv/bin/activate # On Windows: .venv\Scripts\activate
pip install --upgrade pip
pip install -e .For a reproducible install pinned to the tested versions (recommended on lab machines, where "it works on the other PC" needs to stay true):
pip install -r requirements-windows.txt
pip install -e . --no-depspymeasure # Measurement procedure framework
PyQt5 # Graphical user interface
pyqtgraph # Real-time plotting
pyvisa # Keithley VISA communication
pyserial # MUX serial communication
numpy, scipy # Numerical analysis
pandas # CSV parsing & data management
matplotlib # (optional) additional plotting
reportlab # PDF report generation
argon2-cffi # Password hashing
# Via module
python -m solarjv_analyzer.main
# Via hatch
hatch run start- Login — Authenticate with University ID and password (Ctrl+Shift+A reveals Register / Forgot Password)
- Calibration — Mandatory reference cell check. Can be skipped only for emergency data recovery
- Main Window — Configure sweep parameters, select channels, enter filename, run measurements
- Logout — Disconnects instruments, ends session, returns to login
This section documents, for every reported metric, the exact definition, the
extraction algorithm implemented in analysis/analysis.py, the unit
conversions, and the edge-case policy — so the computation can be validated
against first principles without reading the source.
- NaN samples are removed; empty or all-NaN input raises
ValueError. - Data is sorted by voltage. Exact-duplicate voltages (a merged forward+reverse loop passed as one array) are averaged, and every metric below is computed from that single averaged curve. This guarantees internal consistency: FF = Pmax/(Voc·Isc) is only physically meaningful when all three values describe the same curve.
- The function is quadrant-agnostic: it accepts n‑i‑p data in Q4 (V > 0, I < 0) and p‑i‑n data in Q2 (V < 0, I > 0) without any flag, because the generating region is identified by the sign of P = V·I, not by an assumed polarity.
| Metric | Symbol | Unit | Definition & algorithm |
|---|---|---|---|
| Open-Circuit Voltage | Voc | mV | Voltage where I = 0. The first sign change of I along the sorted curve is bracketed; a local window (≤ 15 points) around the crossing is fitted with I = m·V + c (current is the dependent variable — the instrument sources V and measures I, so the noise lives in I) and Voc = −c/m. A local quadratic refinement replaces the linear root only when it reduces the fit residual by ≥ 2× (it captures the exponential knee's curvature, worth ~6 mV; on truly linear data the quadratic is numerically degenerate and is rejected). If the sweep never crosses I = 0 (dark or truncated sweep), Voc = NaN — extrapolation would fabricate a value. Displayed as a magnitude. |
| Short-Circuit Current | Isc | A | Current where V = 0, by the same local-window linear fit evaluated at V = 0. No V = 0 crossing → NaN. Displayed as a magnitude. |
| Short-Circuit Current Density | Jsc | mA/cm² | |Isc [A]| / Area [cm²] × 1000. |
| Maximum Power Point | Vmpp, Pmpp | mV, mW | P(V) = V·I is evaluated on the averaged curve; the generating region is P < 0. The measured global optimum (argmin of signed P — global by definition) anchors a local parabola fit: the window starts at ±max(6·ΔV, 50 mV) and doubles until the curvature is statistically resolved (quadratic residual < 0.7 × linear residual), then the fit is re-centred on its own vertex (≤ 3 iterations). Vmpp is the converged vertex, Pmpp the parabola value there. This tracks sharp MPP knees without the systematic underfit of a global high-order polynomial, and averages noise on flat maxima. Vmpp is reported SIGNED — negative for p‑i‑n (Q2) devices — because it is consumed as the SPO hold voltage and the polarity matters physically. |
| Max-Power Current Density | Jmpp | mA/cm² | Impp = Pmpp/Vmpp (exactly consistent with the reported pair), then |Impp|/Area × 1000. |
| Sanity clamp | — | — | If |Vmpp| > |Voc| (fit inconsistency), Vmpp is clamped to Voc and the operating point is re-evaluated on the measured curve — the reported triple is always a real point of the J-V characteristic, never a product of two independently clamped magnitudes. Skipped when Voc is NaN. |
| Fill Factor | FF | % | |Pmax| / |Voc × Isc| × 100, computed in SI units (V, A, W) before any display conversion. Guarded: requires |Isc| > noise floor (default 1 nA) and |Voc| > 1 µV, otherwise FF = 0 — a near-dead pixel must not report an astronomically large FF. NaN Voc/Isc also yields FF = 0. |
| Efficiency | η (EFF) | % | |Pmax [W]| / (Pin [mW/cm²] × Area [cm²] × 10⁻³ [W/mW]) × 100. |
| Shunt Resistance | Rsh | Ω | Local |dV/dI| at V = 0. The fit window is selected by voltage span — points within ±max(2·ΔV, 25 mV) of the target (≥ 3 points; else the 5 nearest) — then I = g·V + b by least squares and Rsh = 1/|g|. Span-based selection is essential: a fixed 20-point window at 50 mV steps reaches into the exponential diode knee and destroys the estimate (verified: a true 2000 Ω shunt reported as 31 Ω). |g| < 10⁻¹² S → ∞. |
| Series Resistance | Rs | Ω | Same estimator evaluated at V = Voc. Skipped (∞) when Voc is NaN. |
| Shunt Resistivity | ρ (Rho_shunt) | Ω·cm | Bulk shunt resistivity derived from the shunt resistance and the 4-probe geometry: ρ = Rsh × A / t, where A is the device area and t the sample thickness (R = ρ·t/A inverted). Reported as ∞ when Rsh is ∞ or no thickness is supplied. |
| Sheet Resistance | Rsq | Ω/sq | In-plane sheet resistance ρ / t scaled by the 4-probe lateral factor (the finite-lateral-extent correction): Rsq = ρ / t × lateral_factor. Reported as ∞ when ρ is ∞. |
| Contact gate | — | — | contact_threshold is a minimum |Isc|. When |Isc| falls below it, the cell is judged a failed contact or dark and all derived performance metrics are reported as NaN (unknown) with a warning, rather than as if the cell were healthy. Disabled when the threshold is 0. |
| Device Area | A | cm² | User-supplied. |
| Incident Power | Pin | mW/cm² | User-supplied (100 = 1 sun, AM1.5G). |
Internal computation uses SI (V, A, W). Display conversions: Voc, Vmpp ×10³ (V→mV); Pmpp ×10³ (W→mW); Jsc, Jmpp = A/cm² ×10³ (→mA/cm²); Pin input is mW/cm² and is converted by ×A×10⁻³ to W for the efficiency denominator.
The metric pipeline is validated in
tests/analysis/test_scientific_correctness.py against analytic ground
truth, never against the implementation's own output. Synthetic curves are
generated from the single-diode model
I(V) = −(Iph − I₀(e^(V/nVt) − 1) − V/Rsh) with Vt = 25.7 mV; the true Voc is
the machine-precision root of I(V) = 0 (Brent's method), the true MPP is the
optimum of P(V) on a 400 001-point grid, and the true local resistances come
from the analytic derivative dI/dV. Verified accuracies on a realistic 5 mV
sweep of a 20 mA, n = 1.5 cell: Voc within 0.3 mV, Vmpp within 7 mV, Pmpp
within 0.1% (0.6% with 1% current noise), Rsh exact to 4 digits at 50 mV
steps, Rs within 10% of the analytic point value. Additional tests pin the
NaN policy (truncated/dark sweeps), the signed-Vmpp contract (Q2 vs Q4), the
merged-loop consistency rule (FF of the averaged curve, exactly 25% for any
linear cell), and the physical-consistency invariant that the reported
(Vmpp, Jmpp, Pmpp) triple lies on the measured curve.
The application supports both common solar cell architectures via a toggle switch in the J‑V Sweep parameter panel:
| Architecture | Quadrant | Voltage | Current | Example |
|---|---|---|---|---|
| n‑i‑p | Q4 | V > 0 | I < 0 | Standard perovskite, CIGS, CdTe |
| p‑i‑n | Q2 | V < 0 | I > 0 | Inverted perovskite, organic PV |
- The user selects the architecture via a toggle switch (
n‑i‑p/p‑i‑n) in the Parameters tab - The selection is stored as
Device Architecturein the[[ EXPERIMENTAL PARAMETERS ]]block of every saved CSV - On file load, the architecture is automatically parsed and displayed as a badge in the persistent action bar
- Legacy files without the
Device Architecturekey default ton‑i‑p
Important: compute_jv_metrics() is architecture-agnostic — it extracts positive magnitudes from both Q2 and Q4 without any sign-convention flag. The architecture metadata does not affect the mathematics. It now also drives a polarity cross-check: if the measured signed Vmpp contradicts the declared architecture (e.g. a positive Vmpp for a p‑i‑n device), the backend logs a warning and flags polarity_ok = False — surfacing a miswired or mislabelled cell without altering any metric.
The Analysis Settings tab contains four "4-probe" fields whose real effect was audited against the backend. The result:
| Field | Effect on measurement / core metrics | Notes |
|---|---|---|
| Contact Threshold | Yes (gating) | Minimum |Isc|. Below it, the cell is treated as a failed contact / dark cell and all derived metrics are suppressed to NaN. |
| Sample Thickness | Derived only | Feeds Rho_shunt = Rsh·A/t and Rsq = ρ/t. Does not affect Voc/Jsc/FF/EFF/Rs/Rsh or the sweep itself. |
| 4-Probe Lateral Factor | Derived only | Scales the reported sheet resistance Rsq = ρ/t × lateral_factor. Does not affect the measurement or core metrics. |
| 4-Probe Spacing | None | Belongs to a standalone 4-point-probe instrument (collinear-probe geometry). This analyzer never performs a 4-point-probe V/I read — it derives resistance from the J-V curve via the Keithley — so this value is recorded as metadata only and has no effect on any calculation. |
Why the probe spacing is inert: this instrument measures resistance from the current–voltage characteristic of the cell itself (Keithley SourceMeter), not from a separate four-point-probe measurement. The
4-Probe Spacingfield describes the physical geometry of a 4-point-probe instrument that is not part of this measurement chain. It is retained as metadata for lab record-keeping; the same applies in spirit to the "4-Probe Lateral Factor", which only rescales the optional derived sheet-resistance figure.
Sense-mode default: the instrument tab defaults to 4-wire (Kelvin)
remote sense (:SYST:RSEN ON), the correct choice for solar-cell J-V because
it removes cable and contact resistance from the series-resistance (Rs)
reading. Use 2-wire only when the Keithley's SENSE HI/LO leads are not
connected at the cell.
SPO (Set‑Point Operation) is a passive stability test: the Keithley sources a fixed voltage (typically Vmpp found by a quick J‑V sweep) and the current is sampled at a regular interval for a configurable hold duration.
- Quick JV — A fast single sweep locates Vmpp and auto-fills the hold voltage
- Configuration — Set hold duration, sampling interval, and pre-conditioning time
- Pre-Conditioning — The cell stabilises at the hold voltage before logging begins
- Data Collection — Current and power are sampled every N seconds, written to a crash-safe CSV
- Report Generation — On completion (or abort), a formatted report is generated with all SPO metrics
Sign convention (fundamental): all SPO power metrics are computed on the generated power P_gen = −(V·I), which is positive whenever the cell delivers power — in Q4 (V > 0, I < 0) and equally in Q2 (V < 0, I > 0). This makes the metrics physically readable: a degrading cell shows negative drift, "Max Power" is the best sample, and energy is the net energy delivered. (Computing on raw signed V·I — which is negative while generating — inverted the drift sign: a cell decaying from 9 mW to 6 mW reported +33% "drift".)
| Metric | Definition |
|---|---|
| Mean Power (mW) | Mean of P_gen over the hold — positive for a healthy cell |
| Std Power (mW) | Standard deviation of P_gen — stability indicator |
| Initial / Final Power (mW) | Mean P_gen of the first / last 5 samples (edge averages suppress single-sample noise) |
| Drift (%) | (P_final − P_initial) / |P_initial| × 100 on the edge averages. Negative = degradation. If |P_initial| < 1 nW the drift is undefined and reported as NaN — never as a fake number |
| Max / Min Power (mW) | Best and worst P_gen sample during the hold |
| Total Energy (J) | Trapezoidal integration of signed P_gen over time: net generated energy in Joules (W·s); intervals where the cell consumes power subtract, as physics requires |
| Sample Count | Number of valid (non-NaN) samples |
Input handling: time/current/voltage arrays must have equal lengths
(ValueError otherwise); NaN samples are dropped; out-of-order timestamps
are sorted before integration (a trapezoid over non-monotonic time silently
produces cancelling segments).
Validation (tests/spo/test_spo_scientific_correctness.py): expected values
are hand-derived from constructed time series — e.g. a linear 15→10 mW decay
gives exact edge averages (14.90 / 10.10 mW) and drift −32.21%; constant
10 mW × 100 s integrates to exactly 1.000 J; a generate-then-consume series
verifies net (not absolute) energy; Q2 and Q4 holds of the same cell must
produce identical metrics.
Every SPO sample is written to a raw CSV file and flushed to disk with os.fsync() immediately after measurement. If the application or OS crashes mid-run, all data collected up to that point is safely preserved.
The project has a comprehensive test suite: 148 tests in 16 files, covering the analysis pipeline, SPO metrics, auth, hardware protocol logic, and UI widgets. Two dedicated scientific-correctness suites (tests/analysis/test_scientific_correctness.py, tests/spo/test_spo_scientific_correctness.py) verify every metric against analytic ground truth derived from the single-diode model — expected values are never transcribed from the implementation's own output.
# Run all tests
pytest tests/ -v
# Run a specific test file
pytest tests/analysis/test_analysis.py -v
# Run a specific test
pytest tests/analysis/test_analysis.py::test_compute_jv_metrics_ideal_linear_cell -v| Tier | Modules | Tests | Description |
|---|---|---|---|
| Tier 1 — Pure Logic | analysis, spo_analysis, auth/database, config, utils/directory_manager |
44 | No QApplication or hardware needed |
| Tier 2 — Algorithms | jv_procedure, spo_report, mux_controller, app_controller, session |
30 | Core logic with minimal mocking |
| Tier 3 — UI Widgets | analysis_panel, parameter_tab, file_panel, toggle_switch |
29 | Need QApplication, testable in isolation |
| Tier 4 — Integration | End-to-end workflows | 7 | Complex setup, deferred |
All tests adhere to first-principles verification:
- Expected values are hardcoded or independently pre-calculated from physics equations — never generated by calling the same function under test
- Synthetic I‑V curves satisfy fundamental semiconductor relationships:
Pmax < Voc × Isc,0 < FF < 1 - SPO energy integration verified against hand-calculated values (e.g., constant 10 mW × 100 s = exactly 1.0 J)
- Architecture polarity tests confirm identical magnitude outputs for identical linear relationships in Q2 vs Q4
pip install briefcase
briefcase create macOS
briefcase build macOS
briefcase package macOS
# Distribute the resulting .dmg in dist/macOS/pip install briefcase
briefcase create windows
briefcase build windows
briefcase package windows
# Distribute the resulting .msi in dist\Windows\Note: Briefcase packaging requires Python 3.9 (see
.python-version).
jv_setup_keithley_controller/
├── src/solarjv_analyzer/
│ ├── main.py # Entry point: login → calibration → main
│ ├── config.py # Frozen dataclass singleton (ports, paths)
│ ├── analysis/
│ │ └── analysis.py # compute_jv_metrics (11 solar cell metrics)
│ ├── auth/
│ │ ├── database.py # SQLite user DB, Argon2id hashing
│ │ ├── session.py # SessionManager, per-session log files
│ │ └── login_dialog.py # Dark-themed split-screen login UI
│ ├── gui/
│ │ ├── jv_analyzer_window.py # Main window (layout, mode toggle, signals)
│ │ ├── app_controller.py # Experiment queue, file I/O, SPO lifecycle
│ │ ├── style.py # Centralised colour palette, CSS constants
│ │ └── widgets/
│ │ ├── analysis_panel.py # Full-width matrix table (per-channel metrics)
│ │ ├── parameter_tab.py # Sweep config, architecture toggle, channels
│ │ ├── instrument_tab.py # Sense mode, range, NPLC preview
│ │ ├── analysis_settings_tab.py
│ │ ├── file_panel.py # Filename prefix, directory, validation
│ │ ├── toggle_switch.py # iOS-style animated toggle switch
│ │ └── channel_pinout.py
│ ├── instruments/
│ │ ├── instrument_manager.py # Keithley + MUX connection lifecycle
│ │ └── mux_controller.py # Serial hex protocol (AA010{pixel}…)
│ ├── procedures/
│ │ └── jv_procedure.py # Keithley staircase sweep (PyMeasure)
│ ├── spo/
│ │ ├── spo_procedure.py # SPO hold test (inherits JVProcedure)
│ │ ├── spo_analysis.py # compute_spo_metrics (stability, drift, energy)
│ │ ├── spo_report.py # Crash-safe CSV writer (fsync per row)
│ │ └── spo_widget.py # SPO configuration + live P-vs-t plot
│ ├── utils/
│ │ └── directory_manager.py # Singleton: Base/Username/Date/Mode paths
│ └── windows/
│ └── calibration_window.py # Mandatory pre-measurement calibration gate
├── tests/
│ ├── conftest.py # Shared fixtures (synthetic I-V curves)
│ ├── analysis/test_analysis.py # 18 tests — all 11 metrics + edge cases
│ ├── spo/test_spo_analysis.py # 10 tests — SPO metrics + first-principles
│ ├── spo/test_spo_report.py # 5 tests — crash-safe CSV + finalised report
│ ├── auth/test_database.py # 13 tests — registration, auth, password reset
│ ├── config/test_config.py # 3 tests — frozen singleton, constants
│ ├── instruments/test_mux_controller.py # 4 tests — hex command generation
│ ├── procedures/test_jv_procedure.py # 11 tests — voltage seq, NPLC, parsing
│ ├── utils/test_directory_manager.py # 6 tests — paths, modes, preferences
│ ├── gui/widgets/test_analysis_panel.py # 14 tests — matrix table public API
│ ├── gui/widgets/test_parameter_tab.py # 6 tests — architecture toggle, units
│ ├── gui/widgets/test_file_panel.py # 6 tests — filename validation
│ ├── gui/widgets/test_toggle_switch.py # 3 tests — toggle state + signal
│ ├── test_app_controller.py # 4 tests — CSV parsing, architecture
│ └── test_session.py # 6 tests — session lifecycle + logs
├── pyproject.toml # Build config (Hatchling), Briefcase settings
├── Login.png # 3D lab illustration (~6 MB)
├── channel_pinout.png # MUX channel pinout reference
└── README.md
Edit src/solarjv_analyzer/config.py:
| Setting | Default | Description |
|---|---|---|
GPIB_ADDRESS |
"ASRL3::INSTR" |
VISA resource string for Keithley 2400 |
MUX_PORT |
"COM4" |
Serial port for 6-channel MUX |
RESULTS_ROOT |
~/SolarJV_Data |
Base directory for all measurement data |
DATE_FORMAT |
"%d-%m-%Y" |
Date format for data subdirectories |
CHANNEL_COUNT |
6 |
Number of MUX channels |
SIMULATION_MODE |
False |
Deprecated — no simulated fallback in production |
All exported measurement files use a self-documenting block-tag format:
[[ EXPERIMENTAL PARAMETERS ]]
Parameter,Value,Unit
Start Voltage,1.2,V
...
Device Architecture,n-i-p,
[[ ANALYSIS SUMMARY ]]
Channel,EFF (%),FF (%),Voc (mV),...
1_Forward,22.57,75.12,680.50,...
[[ MEASUREMENT DATA ]]
channel,1,1,...
direction,Forward,Forward,...
value,V,J,...
,0.0000,-15.0000,...SPO reports use an additional block:
[[ SPO METRICS ]]
Metric,Value,Unit
mean_power_mw,8.7,mW
drift_percent,1.2,%
[[ TIME SERIES DATA ]]
Time (s),Voltage (V),Current (A),Power (mW)
0.0000,0.6000,-0.01500,9.000Working on this code with an AI agent? The authoritative, machine-facing rules live in
CLAUDE.mdanddocs/(architecture · metric contracts · UI & theme · testing & debugging), with known open defects inAUDIT.md. This section is the human summary; where the two disagree,CLAUDE.mdanddocs/are current.
- Identify the layer: UI widget →
gui/widgets/, procedure →procedures/, hardware →instruments/, analysis →analysis/orspo/ - Follow existing patterns — the SPO module mirrors the JV module's structure
- Use
DirectoryManagersingleton for all file paths — never hardcode paths - Add logging with
logger = logging.getLogger(__name__)at module level - Thread safety — hardware calls MUST run in background workers; cross-thread data MUST use Qt signals
- Add tests — pure logic in Tier 1, widgets in Tier 3, hardware-dependent in Tier 2
- Type hints on all public functions
- Docstrings for all classes and public methods
- Colours and spacing come from
gui/theme/tokens.py(gui/style.pyis a legacy re-export shim) — no hardcoded hex values in widget code - CSV block tags (
[[ EXPERIMENTAL PARAMETERS ]], etc.) must not be modified
- Singleton
DirectoryManager— one instance across the entire application - SPO is optional — the
spo/package usestry/except ImportErrorguards; the JV application runs without it - PyMeasure Manager for JV, custom QThread for SPO — different threading models for different experiment types
- Hardware-controlled sweeps — Keithley configured via SCPI trigger model, not software-point-by-point
This project is licensed under the MIT License. See LICENSE.txt for the full text.
University of Stuttgart · Institute for Photovoltaics (ipv)
Pfaffenwaldring 47 · 70569 Stuttgart · Germany