Add Daikin RB2CA1 (India) / FTKZ50UV16U4 - Cool mode with swing - #1592
Open
adityasanehi wants to merge 2 commits into
Open
Add Daikin RB2CA1 (India) / FTKZ50UV16U4 - Cool mode with swing#1592adityasanehi wants to merge 2 commits into
adityasanehi wants to merge 2 commits into
Conversation
Reverse-engineered 72-bit protocol. Cool mode: 18-30C, fan auto/1-5/turbo, swing vertical/horizontal/both, off. Validated against all captures + tested on real AC via Broadlink RM4.
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
What
Adds climate codes for the Daikin RB2CA1 remote (India market), e.g. paired with indoor unit FTKZ50UV16U4.
Coverage (Cool mode)
All codes were generated from a reverse-engineered model of this remote's IR protocol (not individually learned). Full write-up + reproducible generator: https://github.com/adityasanehi/daikin-rb2ca1-ir-reverse
Spot-tested on the real unit via a Broadlink RM4 (25 °C codes across all fan modes, swing on/off, power off — user-verified).
Notes
bothswing state and turbo+swing combinations are generated per the protocol model but were not individually captured; single-axis swing states were captured and verified.