Each directory under grid/ is a concrete mesh project or case. Case files
describe inputs, parameters, expected results, and how to run the workflow.
Generated grids, reports, and visualization artifacts belong in an external
workspace, not in the checked-in case definition.
case_catalog.json is the machine-readable discovery index for tools and a
future GUI. It gives each case a stable ID and locates its runtime entry point,
layout, and optional richer profile. A GUI should discover cases from this
catalog instead of hard-coding case names or directory paths.
The foundational 2D and 3D layout cases have versioned case.json profiles. Each profile describes the generation dimension, layout, runtime parameter-file list, inspection outputs, and expected mesh counts and bounds. The flat-plate cases also provide profiles
with mesh expectations; turbulent_flat_plate follows the laminar reference
layout but uses 81 points in the wall-normal direction. The catalog remains an
index; profile validation checks that its layout agrees with the catalog and
that its listed parameter files exist.
Use the standard-library command-line tool to discover and validate cases:
python tools/mesh_cases.py list
python tools/mesh_cases.py show minimal_cube
python tools/mesh_cases.py validate
python tools/mesh_cases.py validate two_blocks_shared_face_corners_only
python tools/mesh_cases.py validate two_blocks_shared_edge_endpoints_only
python tools/mesh_cases.py validate two_blocks_shared_edge_one_interior_node
python tools/mesh_cases.py validate turbulent_flat_plate
python tools/test_mesh_cases.pyThe catalog and profiles are not yet the authoritative store for every runtime
parameter. Existing script/*.txt files remain authoritative for OneFLOW, so
standalone execution and older workflows are unchanged. The next migration
stage is to generate selected legacy parameter files from explicitly modeled
profile settings and compare generated values with the existing inputs. Values
not yet modeled must be preserved rather than silently discarded. Do not
duplicate parameter values in the catalog.
| Case | Purpose | Configuration and execution |
|---|---|---|
minimal_rectangle |
Generate a small structured grid, inspect geometry and topology, and export SVG/VTU views | grid/mesh-layout/2d/minimal_rectangle |
minimal_rectangle_vertical_midpoints |
Rectangle layout with one midpoint on each vertical side | grid/mesh-layout/2d/minimal_rectangle_vertical_midpoints |
minimal_cube |
Generate one 3D block from a readable point-line-face-block layout | grid/mesh-layout/3d/minimal_cube |
two_blocks_shared_face_corners_only |
Two 3D blocks sharing a face represented by its four corner nodes | grid/mesh-layout/3d/two_blocks_shared_face_corners_only |
two_blocks_shared_edge_endpoints_only |
Minimum 2D two-block case: one QUAD per block and two shared-edge endpoints | grid/mesh-layout/2d/two_blocks_shared_edge_endpoints_only |
two_blocks_shared_edge_one_interior_node |
Two 2D blocks whose shared edge contains one interior node | grid/mesh-layout/2d/two_blocks_shared_edge_one_interior_node |
mesh_workflow |
Convert the RAE 2822 Plot3D grid to OneFLOW format and write a metadata summary | script/control.txt, parameter files, tools/validate_case.py |
gmsh_to_cgns |
Gmsh MSH 4.1 ASCII to CGNS conversion template | grid/conversion/gmsh_to_cgns |
gmsh_to_oneflow |
Gmsh MSH 4.1 ASCII through CGNS to a native OneFLOW grid | grid/conversion/gmsh_to_oneflow |
stl_to_gmsh_square, stl_to_gmsh_two_square_cells |
Native C++ OneFLOW STL-to-Gmsh Cases with independent Python references | grid/stl_to_gmsh/2d/<case>/cpp, grid/stl_to_gmsh/3d/<case>/cpp and the matching Python references |
laminar_flat_plate |
Reference two-block flat-plate layout template with 85 wall-normal points | grid/mesh-layout/2d/laminar_flat_plate |
laminar_flat_plate_10_edges |
Two-block laminar flat-plate layout with ten geometric line segments and 41 points across the first 0.02 near-wall region | grid/mesh-layout/2d/laminar_flat_plate_10_edges |
turbulent_flat_plate |
Flat-plate layout variant with 81 wall-normal points and updated expected topology counts | grid/mesh-layout/2d/turbulent_flat_plate |
The native stl_to_gmsh Cases run through the OneFLOW Grid task and use the configured Gmsh CLI to generate MSH 4.1. Their outputs can feed the existing Gmsh-to-CGNS/OneFLOW conversion paths. Each STL-to-Gmsh geometry family groups topology variants first and implementation language second; for example, the square variants live under grid/stl_to_gmsh/2d/square/single_quad/{cpp,python} and grid/stl_to_gmsh/2d/square/two_triangles/{cpp,python}.
Foundational layout cases are grouped by dimension:
2d/: rectangle baselines, the two-block shared-edge progression, and flat-plate layouts.3d/: the minimal cube and the two-block shared-face baseline.
The two-block 2D examples are deliberately separate. The endpoint-only case has two nodes on the shared edge and one QUAD per block. The next case adds one interior node to that edge. Each case tests only its stated topology condition; more complex geometry and boundary-condition behavior belong in separate examples.
Each template remains a self-contained case with its own profile where applicable, runtime parameter files, layout source, and editable specification. Generated artifacts belong in an external workspace.
Reusable conversion Cases are grouped under grid/conversion/. Each route
directory is a runnable template with its own input and configuration contract.
Focused examples live beneath the route that owns their execution workflow.
The Gmsh-to-CGNS examples are under
grid/conversion/gmsh_to_cgns/examples/<contract>/<case-id>/. Each example owns its
source mesh, runtime configuration, expected topology, and instructions, so
it can be copied and run independently.
The three reusable route templates are cgns_to_oneflow, gmsh_to_cgns,
and gmsh_to_oneflow. They are runnable Case templates, not converter
implementation modules. mesh-validation stages and composes them in an
external workspace rather than duplicating their runtime configuration.
The conversion matrix at grid/interoperability/conversion_matrix.json
remains the central inventory of supported format routes and the runnable
Cases that cover them. The Case catalog registers examples for GUI and CLI
discovery. These registries describe different things: the catalog locates a
runnable Case, while the matrix records conversion coverage.
The Gmsh-to-CGNS route owns a grid/two_quads.msh input fixture with two
adjacent QUAD_4 cells, six nodes, six exterior LINE_2 elements, and one
internal interface line. Its four exterior Physical Groups demonstrate that
a single named group can span multiple geometric entities. The fixture is
used by the automated conversion integration test and is not a separate
catalog Case. See the Gmsh-to-CGNS examples README and the Grid conversion
Cases documentation for its scope.
- Keep the case profile independent of GUI widgets and OneFLOW runtime globals.
- Let GUI, CLI, and tests use the same case-profile reader and workflow service.
- Generate legacy parameter files only at the case/workspace boundary; do not make OneFLOW depend on a GUI or the case catalog.
- Launch the normal OneFLOW executable for actual generation and conversion.
- Validate produced geometry and topology against case expectations, not just process exit codes or file existence.
- Keep generated grids, reports, and visualization artifacts in an external workspace.
Runtime path roots are optional settings in the existing script/*.txt
parameter files. Existing cases that omit them continue to use the active case
directory.
The general settings are projectRoot, inputRoot, and outputRoot.
Mesh and flow data can then override them independently with
meshInputRoot, flowInputRoot, meshOutputRoot, and flowOutputRoot.
A missing domain-specific setting inherits its corresponding general root.
An empty setting or default selects that inherited value; case selects
the active case; project selects projectRoot; absolute paths are used
directly; other relative IO roots are resolved from the active case. A relative
projectRoot is resolved from the process working directory.
For example, a conversion case can read an initial grid from a shared mesh directory and write the converted grid to its own output directory, while a CFD case can read that converted grid and write flow results elsewhere:
projectRoot = ../OneFLOWProject
meshInputRoot = ../shared-mesh-case
meshOutputRoot = ../mesh-output-case
flowInputRoot = ../mesh-output-case
flowOutputRoot = ../flow-output-case
The root settings do not replace existing file-name settings such as
sourceGridFileName or targetGridFileName. A root is a base directory, not
a replacement for the grid/ or results/ subdirectory already present in a
file-name value. Relative file names are appended to the applicable root,
while absolute file paths remain absolute. Keep existing file-name values
unchanged for compatibility; when moving a case to a different artifact root,
check that the configured relative file names still match the producer output.
Each run writes an io_paths.txt diagnostic beneath each configured output
root (only once when both roots resolve to the same path). When both output
roots are the case root, the legacy-friendly location results/io_paths.txt is
used. The report records the effective roots, so they can be inspected without
inferring them from parameters.
- Keep case-specific parameters and expected results with the case.
- Share code only after multiple concrete cases demonstrate the same need.
- Preserve existing parameter-file compatibility during migration.
The optional PySide6 desktop runner discovers cases from the same catalog, runs selected cases sequentially, streams process logs, and stores each run in an external workspace so source case files are not overwritten.
From the repository root:
python -m pip install -r tools/requirements-gui.txt
python -m tools.oneflow_gui
python -m unittest tools.oneflow_gui.test_servicesSee tools/oneflow_gui/README.md for module boundaries and run behavior.
The GUI currently reports process status; geometry and topology validation
remain a separate workflow step and are not inferred from exit code alone.