#This config file will point TempMon to the correct chip to pull sensor data from
#to find what chip and what feature of the chip you want to monitor (such as cpu temp)
#run the sensors command (make sure you have lm_sensors installed)
#
#
#Example output of Sensors
#
#k10temp-pci-00c3
#Adapter: PCI adapter
#temp1: +20.0°C (high = +70.0°C)
# (crit = +90.0°C, hyst = +88.0°C)
#atk0110-acpi-0
#Adapter: ACPI interface
#Vcore Voltage: +1.36 V (min = +0.80 V, max = +1.60 V)
#+3.3V Voltage: +3.31 V (min = +2.97 V, max = +3.63 V)
#+5V Voltage: +5.06 V (min = +4.50 V, max = +5.50 V)
#+12V Voltage: +11.97 V (min = +10.20 V, max = +13.80 V)
#CPU Fan Speed: 677 RPM (min = 600 RPM)
#Chassis Fan Speed: 1934 RPM (min = 600 RPM)
#Chassis2 Fan Speed: 0 RPM (min = 600 RPM)
#Power Fan Speed: 0 RPM (min = 600 RPM)
#CPU Temperature: +29.0°C (high = +60.0°C, crit = +95.0°C)
#MB Temperature: +22.0°C (high = +45.0°C, crit = +75.0°C)
#Run tempMon -list to see what your current chip features are. Find the
#number that matches the output from the desired chip sensors printed out
#The last number is the alarm temperature. Once hit, the device will sound
#an alarm until reset by the switch
Chip=atk0110
Feature=24
Max=50
#UseTmp tells the daemon whether or not if it should store its PID info in /var/run, or tmp.
#Set this value to true only if you don't want the daemon to run with root privledges
UseTmp=false